Mon. To Sat. 8:30-17:30
info@hanzo.cn
1. Gas shielded welding equipment
2. The process parameters (welding range) of gas shielded welding mainly include:
Wire diameter, welding current, arc voltage.
Welding speed (reference and electrode arc welding)
Wire extension length, gas flow rate, power supply polarity, etc.
The welding current is related to the thickness of the workpiece, the diameter of the wire, the location of the weld, and the form of the droplet transfer:
1. Usually the welding wire's diameter: 0.8-1.6 mm.
2. The welding current is selected within 50-230A during the short circuit transition.
3. The welding current is selected within 250-500A during the coarse drop transition.
In addition to the above parameters, factors such as the angle of the welding torch, the distance between the welding torch and the base metal also have an influence on the welding quality.
Please refer to the wire diameter weldment thickness, welding position and welding current conditions.
|
|
+86-13923298312 info@hanzo.cn New Lighting Source Industry Zone B3, Luocun Town, Nanhai, Foshan, Guangdong, China. |